SPC Flooring
Rigid-core SPC flooring for distributor collections and interior projects. Choose classic planks, synchronized wood textures, patterned layouts or stone-inspired formats.
Request Specifications & Quote ↗

SPC flooring sample
AI-retouched presentation based on a physical sample photograph. Confirm colour, texture and edge details with the original photo and physical sample; no model or thickness is assigned to this image.
Discuss physical samples ↗Explore the collection.
Wanjia offers versatile wood, stone and decorative looks. Tiangong EIR aligns the embossed surface with the printed wood grain. Diequ brings herringbone and chevron patterns, while Qiyan offers a larger stone-look format.
Catalogue specifications
| Collection | Format (mm) | Nominal base thickness | Wear layer |
|---|---|---|---|
| Wanjia | 1220 × 180 | 5 / 6 mm | 12 / 20 mil |
| Tiangong EIR | 1520 × 225 | 6 mm | 12 / 20 mil |
| Diequ Herringbone | 640 × 128 | 6 mm | 12 / 20 mil |
| Diequ Chevron | 1220 × 300 | 6 mm | 12 / 20 mil |
| Qiyan Stone & Rock | 800 × 400 | 5.5 mm | 12 / 20 mil |
Optional 1–2 mm IXPE backing. Catalogue density: 1.90–2.10 g/cm³. Base thickness excludes optional backing; confirm finished thickness with your quotation.
Which thickness should I use for door clearances and floor transitions? Ask for the nominal base thickness, wear layer (mil) and selected backing thickness to be listed separately on the quote. Use the confirmed finished thickness (mm) for that exact plank and backing when checking clearances and transitions. The catalogue wear-layer figure alone does not tell you whether to add it to the nominal base.
Dimensions are catalogue references. Final specifications, availability and order terms are confirmed in your quotation. Interior images illustrate possible applications and are not completed-project claims.
Five flooring selections. Start with a model reference.
Wanjia
M-2 · Winter Warmth

- Format
- 1220 x 180 mm
- Nominal base thickness
- 5 / 6 mm
- Catalogue wear-layer options
- 12 / 20 mil
- IXPE backing
- 1–2 mm optional
Tiangong EIR
TB-8001 · Wheaten Sand

- Format
- 1520 x 225 mm
- Nominal base thickness
- 6 mm
- Catalogue wear-layer options
- 12 / 20 mil
- IXPE backing
- 1–2 mm optional
Diequ Herringbone
R-8001 · Leisure Courtyard

- Format
- 640 x 128 mm
- Nominal base thickness
- 6 mm
- Catalogue wear-layer options
- 12 / 20 mil
- IXPE backing
- 1–2 mm optional
Diequ Chevron
YG-601 · Geisha

- Format
- 1220 x 300 mm
- Nominal base thickness
- 6 mm
- Catalogue wear-layer options
- 12 / 20 mil
- IXPE backing
- 1–2 mm optional
Qiyan Stone & Rock
W-6501 · Stone Light Snow

- Format
- 800 x 400 mm
- Nominal base thickness
- 5.5 mm
- Catalogue wear-layer options
- 12 / 20 mil
- IXPE backing
- 1–2 mm optional
What should I check before specifying SPC flooring?
The SPC flooring in our catalogue uses click-lock joints. Once you select a model, follow the installation guide for its locking system.
- Model and layout. Include the model and laying pattern in your enquiry. For example, Diequ R-8001 is herringbone and YG-601 is chevron.
- Subfloor. Tell us whether the base is concrete, timber or existing tile. Check that it is firm, clean and dry. Record the straightedge length and maximum deviation when checking flatness. For moisture tests, record the method, unit and reading.
- Backing. Check whether the order includes IXPE backing. If the floor already has backing, obtain the manufacturer’s approval before adding a separate underlay.
- Expansion gaps and heating. For a floating installation, mark walls, doorways, fixed objects and the longest continuous run on the floor plan. Confirm gap sizes and where breaks are needed for the selected model. For underfloor heating, specify whether the system is hydronic or electric and confirm the permitted temperature and where it is measured.
Planning figures for floating installations
These figures come from the MMFA’s December 2023 guidance for multilayer modular flooring. Use them for estimating and site surveys. For installation and acceptance, follow local requirements and the instructions applicable to the selected flooring, underlay and heating system.
- Flatness: maximum deviation of 3 mm over a 1 m span.
- Moisture: with the calcium carbide (CM) test, the limits for cement screed are 2.0 CM% unheated and 1.5 CM% heated. For anhydrite screed they are 0.5 CM% and 0.3 CM%, respectively. In-situ humidity probes require separate limits in % RH.
- Conditioning: allow about 48 hours with unopened cartons stored flat at approximately 15–25 °C and 35–65% ambient relative humidity.
- Expansion: for a 5 m wide room, the guide illustrates about 8 mm at each side wall. Check other spans and doorway transitions against the actual layout.
- Heating: the guide lists a maximum floor surface temperature of 29 °C. Confirm system compatibility and apply any lower limit specified for the selected assembly.
Specify your next order.
01 / Select your finish
Share the collection, colour, dimensions and estimated quantity. Request samples for your shortlisted options.
02 / Confirm project needs
Tell us the destination, installation setting and required documents. We will discuss the selected configuration.
03 / Request a quotation
Discuss packing, delivery requirements and order details directly with our team.
Flooring buying guides
Prepare your product brief and compare indoor flooring options before requesting a quotation.
The right surface starts with your brief.
Tell us your product category, quantity, destination and intended application. Ask for available finishes, samples and a quotation for your selected configuration.